The following table compares features of dosimeters.

Ionizing radiation dosimeters
DevicePhotoMfg. countrySize, mmWeight, gPower supplyDisplaySoundVibrationDetector typeRange, μSv/hRange, μR/hMeasurement time, secondsMeasuring of beta and gamma radiation and range of energyPC linkExtra features
Radmetron PM1211Belarus128x48x201301 CR2450LCDYesNoGeiger–Müller tube0.01 – 10e41.14 – 11.4e6yes (48 keV – 3 MeV)USB
Radmetron PM1300Belarus85x57x2195AAALCDYesYesSilicon PIN diode0.01 – 10e61.14 – 11.4e50 – 20X-ray and Gamma (15 keV – 20 MeV)USB, RF-interfaceGPS
Radmetron PM1300GNBelarus130х57х35200built-in rechargeable, or optional AAALCDYesYesSilicon PIN diode, scintillator, silicon photomultiplier0.01 – 10e31.14 – 11.4e70 – 20Yes (0.025 eV – 15 MeV for neutron radiation, 15 keV – 20 MeV for photon radiation)USB, RF-interface
Radmetron PM1401GNMBelarus195х57х324501 ААLCDYesYes3He, Geiger–Müller tube, CsI(Tl) scintillator0.1 – 9999 ±20%0.25Yes (0.033 – 3 MeV for gamma, 0.025 eV– 14 MeV for neutron)USB
Radmetron PM1401MABelarus110×62×383201 ААLCDYesYesCsI(Tl) scintillator0.05 – 40 ±20%0.25Yes (0.05 – 3 MeV)USB
Radmetron PM1401K-3Belarus262x60x658202 ААColor LCDYesYes3He, Geiger–Müller tube, CsI(Tl) scintillator0.1 μSv/h – 100 mSv/hYes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation)USBGPS
Radmetron PM1401K-3MBelarus262x60x658202 ААColor LCDYesYesGeiger–Müller tube, CsI(Tl) scintillator0.1 μSv/h – 100 mSv/hYes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation)USBGPS
Radmetron PM1405PBelarus136×69×383401 ААYesNoGeiger–Müller tube0.1 – 3e5 ±20%11.4 – 34.2e6 ±20%Yes (50 keV – 3 MeV)USB
Radmetron PM1603ABelarus50х56х19851 CR2032LCD with backlightYesNoGeiger–Müller tube0.01 – 10e31.14 – 11.4e2Yes (48 keV – 3 MeV)IR adapteralarm clock, timer, stopwatch, calendar
Radmetron PM1603BYesNoYes (48 keV – 3 MeV)
Radmetron PM1611Belarus60×65×22≤70built-in rechargeableLCDYesYesGeiger–Müller tube0.1 – 10e6 ±15%11.4 – 11.4e8 ±15%0 – 2Yes (20 keV – 10 MeV)USB
Radmetron PM1611BBelarus60×65×25≤80AAALCDYesYesGeiger–Müller tube0.1 – 10e6 ±15%11.4 – 11.4e8 ±15%0 – 2Yes (20 keV – 10 MeV)USB
Radmetron PM1621Belarus87х72х391501 ААLCDYesNoGeiger–Müller tube0.1 – 10e4 ±15%11.4 – 11.4e6 ±15%Yes (10 KeV – 20 MeV)IR adapter
Radmetron PM1621ABelarus87х72х391651 ААLCDYesNoGeiger–Müller tube0.1 – 10e5 ±15%11.4 – 11.4e7 ±15%Yes (10 KeV – 20 MeV)IR adapter
Radmetron PM1621MBelarus87х72х391851 ААLCDYesNoGeiger–Müller tube0.01 – 10e4 ±15%11.4 – 11.4e6 ±15%Yes (10 keV – 20 MeV)IR adapter
Radmetron PM1621MABelarus87х72х391851 ААLCDYesYesGeiger–Müller tube0.01 – 10e5 ±15%11.4 – 11.4e7 ±15%Yes (10 KeV – 20 MeV)IR adapter
Ludlum Model 23Texas, United States112.8x30x1255.9CR2450OLEDYesNoMOSFET1 – 99.1e4 ≤±10%114 – 11.4e7 ≤±10%X-ray and GammaIR reader
Ludlum Model 23-1Texas, United States112.8x30x1255.9CR2450OLEDYesNoMOSFET1 – 99.9e3 ≤±10%114 – 11.47 ≤±10%Gamma and X-rayIR reader
Ludlum Model K8Texas, United States39x25x1313CR2032LEDYesNoMOSFET0.01 – 99.9e7gammaNo
Ludlum Model 25Texas, United States76x54x171442 lithium button cellsLCD with backlightYesNoGeiger–Müller tube0.1 – 87.6e510 – 99.9e7Yes (60 keV – 2 MeV)
Ludlum Model 25-1Texas, United States76x54x171442 lithium button cellsLCD with backlightYesNoGeiger–Müller tube1 – 99.9e5114 – 11.4e8Yes (60 keV — 2 MeV)
Ludlum Model 25-ISTexas, United States76x54x171442 lithium button cellsLCD with backlightYesNoGeiger–Müller tube0.09 —87.6e510 —99.9e7Yes (60 keV — 2 MeV)
Ludlum Model 25-IS-1Texas, United States76x54x171442 lithium button cellsLCD with backlightYesNoGeiger–Müller tube1 — 99.9e5114 — 11.4e8Yes (60 keV — 2 MeV)
FNIRSI GC-01Mainland China120x78x271100mAh Lithium-ion batteryLCD with backlightYesYesGeiger–Müller tube0.01 — 50e31 — 50e5combined, 48 keV - 1.5 Mev ≤ ±30%Hydrogen Cyanide Detector
FNIRSI GC-02Mainland China850 mAh Lithium-ion batteryLCD with backlightYesGeiger–Müller tubeYes
Radiascan 501Russia110х60х231102 AAA batteryColor OLED displayYesNoGeiger–Müller tube Beta 1-10.01—10e31—10e51 — 60NoYesfood contamination tester, "background pattern analysis algorithm"
SA-05ASwitzerland119x65x26.5135Built-in lithium polymer batteryLCDNoNoGeiger–Müller tube LND 7130.01–6000No1 – 600.05–1.3 MeVUSBClock, calendar and data logger
Radiascan 701Russia110х60х231102 AAA batteryColor OLED displayYesNoGeiger–Müller tube Beta 1-10.01—10e31—10e51 — 60CombinedUSBfood contamination tester
ANRI 01-02 SosnaRussia133x82x45350Nine-volt batteryLCDYesNoTwo to four Geiger–Müller tubes0.1–10010–10e420±5Combined, 0.5–3.0 MeVNo
bGeigie NanoJapan149x103x54440Li-PoLCDNoYesone Geiger–Müller tube0–10000–1001 – 60YesUSB, Bluetooth, and WiFiWaterproof,Clock GPS, open-source
bGeigieZen StandardJapan165x98x52450replaceable 18650 3000mA + USB-C +QI wirelessIPS LCD with touchscreenyes (can be switched on/off)Noone LND7317 Geiger–Müller tube0-10000-1001 — 60YesUSB, Bluetooth, and WiFiWaterproof, GPS, open-source. WiFi and BLE real time and upload of data.
bGeigieZen NFWJapan165x98x52450replaceable 18650 3000mA + USB-C +QI wirelessIPS LCD with touchscreenyes (can be switched on/off)Noone LND7317 Geiger–Müller tube0-10000-1001 — 60YesUSB, Bluetooth, and WiFiWaterproof, GPS, open-source. WiFi and BLE real time and upload of data.
DKG-RM1203MBelarus125x42x2490Two LR44LCDYesNoGeiger–Müller tube0.01–20001–2*10e5NoInfraredClock with alarm
DKR-0474х48х1650AAALCDYesNoSemiconductor0.1–10e610–10e84 — 256NoNo
Ecotest DKG-21MUkraine98×58×18140CR2450 Button cellYesGeiger–Müller tube0.1 – 10e5 ±15%Yes (0.05 – 6 MeV)infrared
Ecotest DKG-24 "PRD Guarder"Ukraine60×110×302502 ААbacklit monochrome displayYesYesCsI(Tl) scintillator, silicon semiconductor0.01 – 10710 – 90Yes (0.02 – 10.0 MeV)Bluetooth, USBgyroscope, GPS
Ecotest MKS-03D "Swift"Ukraine111x73x282002 ААLCD with backlightYesYesGeiger–Müller tube0.1—10510—1074 — 128Combined, 0.12—3.0 MeV Beta measurement range 5—105 min−1 cm−2USBClock with alarm, optional case
Ecotest MKS-05 "Terra-P"Ukraine120×52×26150Two AAALCDYesNoGeiger–Müller tube0.1–100010–10e55 — 70Combined, 0.5–3.0 MeVNoClock with alarm, cover as option
Ecotest MKS-05 "Terra" (New edition)Ukraine120×52×26150Two AAALCD with backlightYesYesGeiger–Müller tube0.1–10e410–10e61 — 70Combined, 0.5–3.0 MeVBluetoothClock with alarm, cover
Ecotest MKS-05 "Terra" (with Bluetooth channel)Ukraine120×52×26150Two AAALCD with backlight
Ecotest MKS-UMUkraine166×70×132 (control unit), 47×95×173 (probe)70 (control unit), 30 (probe)YesGeiger–Müller tube1 – 10e6Yes (0.05 – 3 MeV)
Ecotest RKS-01 "STORA-TU"Ukraine160×75×3650Two AAAYes4 Geiger–Müller tubes0.1 – 999.9Bluetooth
GQ GMC-300E +V4Washington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube32832.81 — 60CombinedUSB
GQ GMC-320 +V4Washington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube32832.81 – 60CombinedUSBgyroscope, temperature sensor
GQ GMC-320 +V5Washington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube32832.81 – 60CombinedUSBWiFi, logging to a server, gyroscope, temperature sensor
GQ GMC-300SWashington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube10001001 – 60CombinedUSB
GQ GMC-320SWashington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube10001001 – 60CombinedUSBgyroscope, temperature sensor
GQ GMC-SEWashington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube20002001 – 60CombinedUSB
GQ GMC-500Washington, United States18650LCD with backlightYesNoOne Geiger–Müller tube50005001 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-500+Washington, United States135x78x2518650LCD with backlightYesNoTwo Geiger–Müller tubes0 – 42.5e30 – 4.25e61 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-800Washington, United StatesAALCD with backlightYesNoOne Geiger–Müller tube20002001 – 60CombinedUSB
GQ GMC-600Washington, United States18650LCD with backlightYesNoSBT-1142504251 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-600+Washington, United States18650LCD with backlightYesNoLND 731710e310001 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-510Washington, United States18650LCD with backlightYesNoM401142504251 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-520Washington, United States18650LCD with backlightYesNoM401142504251 – 60CombinedUSBWiFi, logging to a server, gyroscope
GQ GMC-520+Washington, United States18650LCD with backlightYesNoM401142504251 – 60CombinedUSBWiFi, logging to a server, gyroscope
Radex RD1503, RD1503+Russia105х60х2690One or two AAALCD with backlightYesOnly RD1503+Geiger–Müller tube0.05 – 105 – 1000up to 40Combined, 0.1–1,25 MeVNo
Radex RD1706Russia105х60х2690One or two AAALCD with backlightYesYesTwo Geiger–Müller tubes0.05 –10005 – 10e51 – 26Combined, 0.1–1.25 MeVNoBackground mode
Radex RD1212Russia97x68x2480One or two AAALCD with backlightYesYesOne Geiger–Müller tube0.05 – 9995 – 10e51 – 10Combined, 0.4–3.5 MeVUSBBackground mode, integrated flashlight, time and date functions, multilingual
Radex RD1008Russia140х64х26175AALCD with backlightYesYesTwo Geiger–Müller tubes0.1 – 10002 – 1202 – 21Separated, 0.05–3.5 MeVNoBackground mode, separated indication of beta and gamma radiation
RadiaCode 102Republic of Cyprusconflicting answers (124x35x20 or 123x34x18)65built-in Lithium polymer batteryLCD with backlightYesCsI(Tl) scintillator0.01 – 10001 — 10e50.5yesUSB and Bluetooththermometer, clock
RadiaCode 103Republic of Cyprusconflicting answers (124x35x20 or 123x34x18)65built-in Lithium polymer batteryLCD with backlightYesCsI(Tl) scintillator0.01 – 10001 — 10e50.5yesUSB and Bluetooththermometer, clock
RadiaCode 103GRepublic of Cyprusconflicting answers (124x35x20 or 123x34x18)70built-in Lithium polymer batteryLCD with backlightYesGAGG(Ce) Scintillator0.01 – 10001 — 10e50.5yesUSB and Bluetooththermometer, clock
RadTarge II D300Mainland China69x46x1760Built-in lithium ion batteryLCD with backlightYesYesYSO scintillator + SiPM0.5 – 500050 – 5e5< 8No, 0.03–1.5 MeVUSBDose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software)
RadTarge II D700Mainland China69x46x1760Built-in lithium-ion batteryLCD with backlightYesYesYSO scintillator + SiPM0.01 — 10001 — 10e5< 2No, 0.02–3 MeVUSBDose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software)
RadTarge II D900Mainland China69x46x1760Built-in lithium-ion batteryLCD with backlightYesYesYSO scintillator + SiPM0.1 – 10e510 – 10e7< 6No, 0.02–3 MeVUSBDose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software)
RKSB-104Belarus154х77х393501 Nine-volt batteryLCDNoNoTwo Geiger–Müller tubes0.1 — 10010 — 2e418 – 400Combined, 0.5–3.0 MeVNo
RKS-107Belarus154x77x393501 Nine-volt batteryLCDNoNoGeiger–Müller tube0.1 — 99.9910 — 9999
Pripyat RKS-20.03UkraineTwo SBM-20 Geiger–Müller tubes
DKG-RM1610Belarus58х58х1870Built-in accumulatorLCDYesYesOne Geiger–Müller tube0.01 — 1.2e61 — 1.2e8NoUSBShock protection
EcotestCARDUkraine80CR2450LCDYesNoSemiconductor0.1–10e610–10e8Infrared
SOEKS 01MRussiaGeiger–Müller tube

Notes

Literature

  • (PDF). International Atomic Energy Agency. Chicago. 2007.
  • Bordy JM, Daures J, Clairand I, Denozière M, Donadille L, d'Errico F, Gouriou J, Itié C, Struelens L (2008). "Evaluation of the calibration procedure of active personal dosemeters for interventional radiology". Radiation Protection Dosimetry. 131 (1): 87–92. doi:. PMID .
  • . Radiation Emergency Medical Management (REMM). United States Department of Health and Human Services.