The Significant New Alternatives Policy (also known as Section 612 of the Clean Air Act or SNAP, promulgated at 40 CFR part 82 Subpart G) is a program of the EPA to determine acceptable chemical substitutes, and establish which are prohibited or regulated by the EPA. It also establishes a program by which new alternatives may be accepted, and promulgates timelines to the industry regarding phase-outs of substitutes.

Scope

Originally, Section 612 was limited by ozone-depleting chemicals. However, after passing regulations to phase-out R134a, an HFC refrigerant with no ozone-depleting potential, this phase-out was defended by a subsidiary of DuPont siding with the EPA as it was challenged by a major manufacturer of R134a, and was struck down in 2017. This decision was upheld in 2018. In 2021, a new law was passed as part of the appropriations bill extending the EPA's scope to substances with high GWP as well.

The EPA looks at available chemical substitutes in the following industrial sectors:

  • Adhesives, Coatings, and Inks
  • Aerosols
  • Cleaning Solvents
  • Fire Suppression and Explosion Protection
  • Foam Blowing Agents
  • Refrigeration and Air Conditioning
  • Sterilants
  • Tobacco Expansion

Evaluations are ongoing as technological understanding improves, and can only prohibit substance where the EPA has determined other available substitutes that pose less overall risk to human health and the environment.

Submittal process

In order to submit new proposed chemicals, along with general contact and marketing information, for a complete submittal, the EPA requires reports on:

  • Impurities
  • Byproducts
  • Degradation Products
  • Test Marketing
  • Physical Properties including: molecular weight physical state melting point boiling point specific gravity If a blend bubble point dew point If flammable lower flammability limit upper flammability limit flash point
  • Ozone Depletion Potential (ODP)
  • Global Warming Potential (GWP)
  • VOC content
  • Proposed cost
  • Toxicity Limits Permissible Exposure Limits (PELs) Short-Term Exposure Limits (STELs) Threshold Limit Values (TLVs) Recommended Exposure Limits (RELs) Workplace Environmental Exposure Limits (WEELs) acceptable exposure limits (AELs) Toxicological studies
  • SDS
  • Environmental/Health and Safety Law Review
  • Industry/Application-specific Use Profile

Refrigerants

One important, changing aspect of SNAP is its effect on the HVAC industry. Particularly because it decides which refrigerants may be legally used, it coordinates refrigerant phaseouts in the U.S., and which are prohibited against venting in concordance with Section 608. The following is a list of accepted refrigerants, or phase-out periods according to the EPA.

MVAC Passenger Air Conditioning in VehiclesMVAC Passenger Air Conditioning in Buses and TrainsCentrifugal ChillersPositive Displacement ChillersIndustrial Process RefrigerationCold Storage WarehouseCommercial Ice MachinesHousehold Refrigerators and FreezersIce Skating RinksIndustrial Process Air ConditioningResidential and Light Commercial Air Conditioning and Heat PumpsResidential DehumidifiersRefrigerated TransportStand Alone EquipmentRefrigerated Food Processing and Dispensing EquipmentRemote Condensing UnitsTypical Supermarket SystemsVending machinesVery Low Temperature RefrigerationWater Coolers
Ammonia / Water AbsorptionAcceptable
Ammonia AbsorptionAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
Ammonia Vapor CompressionAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
Ammonia Vapor Compression with Secondary LoopAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
ChlorineAcceptable
Cryogenic Transport Refrigeration SystemAcceptable
Desiccant CoolingAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
Direct Nitrogen ExpansionAcceptableAcceptable
Evaporative CoolingAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
FOR12AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019.Acceptable
FOR12BUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
Freeze 12Unacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
G2018CAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
GHG-HPUnacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
GHG-X5Unacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
HC Blend AAcceptable
HC Blend BAcceptable
HCFC-123AcceptableAcceptable
HCFC-124AcceptableAcceptable
HCFC-22AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
HCFC-22/HCFC-142bAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
HCFO-1233zd(E)AcceptableAcceptableAcceptableAcceptable
HFC-134aUnacceptable as of Model Year (MY) 2021, except where allowed under a narrowed use limit through MY 2025. Unacceptable for all newly manufactured vehicles as of MY 2026.AcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit for military marine vessels and human-rated spacecraft and related support equipment, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for military marine vessels and human-rated spacecraft and related support equipment, as of January 1, 2024.AcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptable, Applicable to new uses below 125 degrees F ambientAcceptableAcceptableAcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019.Acceptable
HFC-134a/HBr (92/8)AcceptableAcceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.AcceptableAcceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.
HFC-152aAcceptable with Use ConditionsAcceptable
HFC-227eaUnacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Acceptable with Use Conditions: When manufactured using any process that does not convert perfluoroisobutylene (PFIB) directly to HFC-236fa in a single step.Unacceptable in new equipment as of January 1, 2023.UnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in new equipment as of January 1, 2017Unacceptable in new equipment as of January 1, 2017
HFC-23AcceptableAcceptable
HFC-32Acceptable with Use Conditions
HFC-236faUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Acceptable
HFC-245faUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptable
HFE-347mcc3 (heptafluoropropyl methyl ether)AcceptableAcceptable
HFE-449s1 (methoxynonafluorobutane, iso and normal)Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.
HFE-569sf2 (ethoxynonafluorobutane, iso and normal)Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.
HFO-1234zeAcceptableAcceptable
HFO-1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluorobut-2-ene)AcceptableAcceptableAcceptable
HFO-1336mzz(Z)/dichloroethylene blend (R-514A)AcceptableAcceptable
Ikon AAcceptable with Use ConditionsAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
Ikon BAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
ISCEON 89Acceptable
NARM-502AcceptableAcceptable
Pressure stepdownAcceptable
R-1224yd(Z)AcceptableAcceptableAcceptable
R-125/R-134a/R-600a (28.1/70.0/1.9)AcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-125/R-290/R-134a/R-600a (55.0/1.0/42.5/1.5)Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-170 (Ethane)Acceptable with Use Conditions
R-1270 (Propylene)Unacceptable as of January 3, 2017.Unacceptable as of January 3, 2017.AcceptableUnacceptable, as of January 3, 2017.Unacceptable, as of January 3, 2017.
R-290 (Propane)AcceptableAcceptable with Use ConditionsAcceptable with Use ConditionsAcceptable with Use Conditions: For use in self-contained room air conditioningee rule for detailed conditionsAcceptable with Use ConditionsAcceptable with Use ConditionsAcceptable with Use ConditionsAcceptable with Use Conditions
R-401AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-401BAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-402AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-402BAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-403BAcceptableAcceptable
R-404AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit for human-rated spacecraft and related support equipment, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for human-rated spacecraft and related support equipment, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2019.AcceptableAcceptable
R-406AUnacceptable as of MY 2017AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-407AAcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptable
R-407BAcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.
R-407CAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019.AcceptableAcceptable
R-407DAcceptable
R-407FAcceptableAcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptable
R-407HAcceptable: For use in refrigerated trucks and trailers onlyAcceptableAcceptableAcceptable
R-408AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-409AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-410AAcceptableUnacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019AcceptableAcceptable
R-410BUnacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019AcceptableAcceptable
R-411AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-411BAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-414AUnacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-414BUnacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-416AUnacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-417AAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-417CAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-420AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-421AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-421BAcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Acceptable
R-422AAcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.
R-422BAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableAcceptable
R-422CUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Unacceptable in new equipment as of January 1, 2019AcceptableAcceptable
R-422DAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Unacceptable in new equipment as of January 1, 2019Acceptable
R-423AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableAcceptable
R-424AAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptable
R-426AUnacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-427AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-428AAcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.
R-434AAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Acceptable
R-437AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-438AAcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
R-441AAcceptable with Use ConditionsAcceptable with Use Conditions: For use in self-contained room air conditioningAcceptable with Use ConditionsAcceptable with Use Conditions
R-442AAcceptableAcceptableAcceptableAcceptable
R-443AUnacceptable as of January 3, 2017.Unacceptable as of January 3, 2017.Unacceptable, as of January 3, 2017.Unacceptable, as of January 3, 2017.
R-448AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable: Low temperature UseAcceptableAcceptableAcceptable
R-449AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable: Low temperature UseAcceptableAcceptableAcceptable
R-449BAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable: Low temperature UseAcceptableAcceptableAcceptable
R-450AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
R-452AAcceptable
R-452BAcceptable with Use ConditionsAcceptable: For use in refrigerated trucks and trailers only.
R-452CAcceptable: For use in refrigerated trucks and trailers only.Acceptable
R-453AAcceptableAcceptableAcceptable: For use in refrigerated trucks and trailers only.Acceptable
R-454AAcceptable with Use Conditions
R-454BAcceptable with Use Conditions
R-454CAcceptable with Use Conditions
R-457AAcceptable with Use Conditions
R-458AAcceptableAcceptableAcceptable
R-507, R-507AUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017.Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2019.AcceptableAcceptable
R-508AAcceptableAcceptable
R-508BAcceptableAcceptable
R-513AAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable with Use Conditions: Low temperatureAcceptableAcceptableAcceptableAcceptableAcceptable
R-515BAcceptableAcceptableAcceptable
R-600 (Butane)AcceptableAcceptable with Use ConditionsAcceptable with Use ConditionsAcceptable with Use Conditions
R-744 (Carbon Dioxide, CO2)Acceptable with Use ConditionsAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
RB-276Unacceptable as of MY 2017.AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
RS-24 (2002 formulation)Acceptable with Use ConditionsAcceptableAcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
RS-44 (2003 formulation)Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableUnacceptable in new equipment as of January 1, 2023.AcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptableAcceptableAcceptableUnacceptableUnacceptable in new equipment as of January 1, 2021.AcceptableAcceptable
Self-chilling cans using CO2AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
SP34EUnacceptable as of MY 2017.AcceptableUnacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableUnacceptableAcceptableAcceptableAcceptableUnacceptable in new equipment as of January 1, 2019Acceptable
Stirling CycleAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
THR-01Acceptable
THR-02AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
THR-03Unacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024.AcceptableAcceptableAcceptableUnacceptable in new equipment, as of January 1, 2021.AcceptableAcceptableAcceptable with Use Conditions: For use in residential window unit air conditioning.AcceptableUnacceptableAcceptableAcceptableAcceptable
THR-04AcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptableAcceptable
Trans-1-chloro-3,3,3-trifluoroprop-1-eneAcceptable
Water / Lithium Bromide AbsorptionAcceptable

See also

External links